Rabu, 23 Juni 2010

POTENTIAL HAZARDS

FIRE OR EXPLOSION
• May explode from heat, shock, friction or contamination.
• May react violently or explosively on contact with air, water or foam.
• May be ignited by heat, sparks or flames.
• Vapors may travel to source of ignition and flash back.
• Containers may explode when heated.
• Ruptured cylinders may rocket.

HEALTH
• Inhalation, ingestion or contact with substance may cause severe injury, infection,disease or death.
• High concentration of gas may cause asphyxiation without warning.
• Contact may cause burns to skin and eyes.
• Fire or contact with water may produce irritating, toxic and/or corrosive gases.
• Runoff from fire control may cause pollution.
PUBLIC SAFETY
• CALL Emergency Response Telephone Number on Shipping Paper first. If Shipping Paper not available or no answer, refer to appropriate telephone number listed on the inside back cover.
• As an immediate precautionary measure, isolate spill or leak area for at least 100 meters
(330 feet) in all directions.
• Keep unauthorized personnel away.
• Stay upwind.
• Keep out of low areas.
PROTECTIVE CLOTHING
• Wear positive pressure self-contained breathing apparatus (SCBA).
• Structural firefighters' protective clothing provides limited protection in fire situations ONLY; it may not be
effective in spill situations.

EVACUATION
Fire
• If tank, rail car or tank truck is involved in a fire, ISOLATE for 800 meters (1/2 mile) in all directions; also, consider initial evacuation for 800 meters (1/2 mile) in all directions.

EMERGENCY RESPONSE
FIRE
CAUTION: Material may react with extinguishing agent.
Small Fire
• Dry chemical, CO2, water spray or regular foam.
Large Fire
• Water spray, fog or regular foam.
• Move containers from fire area if you can do it without risk.
Fire involving Tanks• Cool containers with flooding quantities of water until well after fire is out.
• Do not get water inside containers.
• Withdraw immediately in case of rising sound from venting safety devices or
discoloration of tank.
• ALWAYS stay away from tanks engulfed in fire.

SPILL OR LEAK
• Do not touch or walk through spilled material.
• ELIMINATE all ignition sources (no smoking, flares, sparks or flames in immediate area).
• All equipment used when handling the product must be grounded.
• Keep combustibles (wood, paper, oil, etc.) away from spilled material.
• Use water spray to reduce vapors or divert vapor cloud drift. Avoid allowing water runoff to contact spilled material.
• Prevent entry into waterways, sewers, basements or confined areas.
Small Spill • Take up with sand or other non-combustible absorbent material and place into
containers for later disposal.
Large Spill • Dike far ahead of liquid spill for later disposal.

FIRST AID
• Move victim to fresh air. • Call 911 or emergency medical service.
• Give artificial respiration if victim is not breathing.
Do not use mouth-to-mouth method if victim ingested or inhaled the substance; give artificial respiration with the aid of a pocket mask equipped with a one-way valve or other proper respiratory medical device.
• Administer oxygen if breathing is difficult.
• Remove and isolate contaminated clothing and shoes.
• In case of contact with substance, immediately flush skin or eyes with running water for at least 20 minutes.
• Shower and wash with soap and water.
• Keep victim warm and quiet.
• Effects of exposure (inhalation, ingestion or skin contact) to substance may be delayed.
• Ensure that medical personnel are aware of the material(s) involved and take precautions to protect themselves.

HAZARD CLASSIFICATION SYSTEM

The hazard class of dangerous goods is indicated either by its class (or division) number or name.
Placards are used to identify the class or division of a material. The hazard class or division number
must be displayed in the lower corner of a placard and is required for both primary and subsidiary
hazard classes and divisions, if applicable. For other than Class 7 or the OXYGEN placard, text
indicating a hazard (for example, “CORROSIVE”) is not required. Text is shown only in the U.S. The
hazard class or division number and subsidiary hazard classes or division numbers placed in
parentheses (when applicable), must appear on the shipping document after each proper shipping
name.
Class 1 - Explosives
          Division 1.1 Explosives with a mass explosion hazard
          Division 1.2 Explosives with a projection hazard
          Division 1.3 Explosives with predominantly a fire hazard
          Division 1.4 Explosives with no significant blast hazard
          Division 1.5 Very insensitive explosives with a mass explosion hazard
          Division 1.6 Extremely insensitive articles
Class 2 - Gases
          Division 2.1 Flammable gases
          Division 2.2 Non-flammable, non-toxic gases
          Division 2.3 Toxic gases
Class 3 - Flammable liquids (and Combustible liquids [U.S.])
Class 4 - Flammable solids; Spontaneously combustible materials; and Dangerous when wet 
                materials/Water- reactive substances
          Division 4.1 Flammable solids
          Division 4.2 Spontaneously combustible materials
          Division 4.3 Water-reactive substances/Dangerous when wet materials
Class 5 - Oxidizing substances and Organic peroxides
          Division 5.1 Oxidizing substances
          Division 5.2 Organic peroxides
Class 6 - Toxic substances and Infectious substances
          Division 6.1 Toxic substances
          Division 6.2 Infectious substances
Class 7 - Radioactive materials
Class 8 - Corrosive substances
Class 9 - Miscellaneous hazardous materials/Products, Substances or Organisms

Senin, 21 Juni 2010

Static Sparks Explosion


Static Sparks Explosion in Kansas
On July 17, 2007, explosions and fire erupted at the Barton Solvents facility in Valley Center, Kansas, north of Wichita. The incident led to the evacuation of thousands of residents and resulted in projectile damage offsite, as well as extensive damage to the facility.
Wichita, Kansas, June 26, 2008 - The U.S. Chemical Safety Board (CSB) today released a case study and safety video on the July 2007 explosion and fire at the Barton Solvents distribution facility in Valley Center, Kansas. The CSB found the most likely cause of the explosion -- involving what is known as a nonconductive flammable liquid -- was a static spark resulting from a loosely-linked level-measuring float within the tank. The spark ignited the air-vapor mixture inside the tank as it was being filled.
Nonconductive flammable liquids can accumulate and maintain static electrical energy which discharges more slowly than from more conductive liquids. In addition, some of these liquids can form ignitable vapor-air mixtures inside storage tanks which can explode if a spark occurs.
The July 17, 2007 explosion and fire led to the evacuation of 6,000 residents. Eleven residents and one firefighter sought medical attention. Fire destroyed the facility. CSB investigators found that on the day of the accident a tanker-trailer arrived to transfer Varnish Maker's and Painter's Naphtha (VM&P Naphtha) into a storage tank. The CSB determined that the transfer equipment from the truck tanker to the storage tank likely was properly bonded and grounded to prevent the generation of static electricity. However, the CSB found, the float device inside the 15,000 gallon storage tank presented a hidden danger.
CSB Lead Investigator Randy McClure said, "When transferring liquids, it is standard industry practice to bond and ground storage vessels, tankers, and other equipment to prevent static discharges. But our investigation illustrates how normal bonding and grounding may not be enough to prevent ignition from static electric sparks."
Inside the tank was a device used for measuring the liquid level, a metal float linked to a metal tape measure. The CSB determined that a static electrical charge in the liquid was generated by the flow of the solvent pumped from the trailer into the storage tank, and by stop-and-start filling which introduced air into the liquid, resulting in bubbles and turbulence.
At the same time, the space above the liquid was being filled with an explosive mixture of vapor and air. The CSB determined that the liquid flow and turbulence created by the filling of the tank likely resulted in the metal float accumulating a static electrical charge. As the float moved, a gap is believed to have formed within the linkage of the tape and the float. CSB investigators said a spark likely jumped between the metal parts and ignited the explosive mixture of vapor and air that had accumulated above the liquid.
The explosion blew the tank 130 feet into the air, and within moments two more tanks ruptured and released their contents. As the fire burned, the contents of nearby tanks were released and ignited, launching debris into the air where some of it struck a mobile home and a neighboring business.
Board Member Wark said, "Several common flammable liquids are particularly susceptible to ignition by static sparks. Some of these flammable liquids can produce the optimal amount of vapor to fuel an explosion at normal temperatures inside a storage tank."
Mr. Wark continued, "While we found the most likely cause of the Barton explosion was sparking across the float linkage, we emphasize that explosions can occur in tanks without faulty floats when there is a discharge from the build-up of static in the nonconductive flammable liquid itself."
Material Safety Data Sheets, or MSDSs, communicate hazard information on chemical products. The CSB determined the MSDS for the VM&P Naphtha did not adequately describe the explosive hazard or the precautions necessary to prevent ignition from static electricity. Most of the MSDSs for the flammable solvents supplied to Barton indicated that the solvent could accumulate a static charge, which could spark and ignite vapor. But the MSDSs did not warn that the solvent could form a highly explosive vapor-air mixture inside a storage tank.
The CSB reviewed 62 MSDSs for some of the most widely used nonconductive flammable liquids in industry, such as VM&P Naphtha, hexane and toluene. Most failed to recommend specific precautions beyond bonding and grounding.
"The accident at Barton Solvents emphasizes the need for accurate and detailed MSDSs," said Mr. Wark. "We found that while most MSDSs for this category of flammable liquids do warn about the dangers of accumulating static electricity because the liquids are poor conductors, the MSDSs do not warn specifically that they can be ignited in storage tanks. Companies should be aware that some of these flammable liquids can form an ignitable vapor-air mixture inside storage tanks."
The CSB issued recommendations to OSHA and others to improve required information contained in MSDSs to include addressing nonconductive flammable liquids which are routinely shipped to distributors such as Barton. The CSB also recommended that six major oil and chemical industry associations ask their member companies to improve the warnings on the MSDSs of flammable liquids because these materials can accumulate static electricity.
The Board recommended companies handling the liquids should take additional safety measures, such as:
  • Obtain more detailed additional technical information on the liquids from manufacturers that may not be found on MSDSs.
  • Purge storage tanks with an inert gas to remove oxygen.
  • Add anti-static agents to the liquids.
  • Pump liquids more slowly.
  • Verify that storage tank level floats are effectively bonded.
The CSB is an independent federal agency charged with investigating industrial chemical accidents. The agency's board members are appointed by the president and confirmed by the Senate. CSB investigations look into all aspects of chemical accidents, including physical causes such as equipment failure as well as inadequacies in regulations, industry standards, and safety management practices. The Board does not issue citations or fines but does make safety recommendations to plants, industry organizations, labor groups, and regulatory agencies such
The CSB released a ten-minute safety video which features a computer animation depicting the sequence of events that led to the explosion and fire. The video, entitled "Static Sparks Explosion in Kansas" is available for downloading free of charge through the agency's video website, www.safetyvideos.gov.
CSB Board Member William Wark said, "Our goal is to help companies understand the hazards associated with the kinds of flammable liquids that were stored and transferred at Barton Solvents. We believe our case study and the safety video will help accomplish that goal and prevent accidents."